How to Calibrate Vibration Sensors on Shale Shaker

Properly calibrated vibration sensors are critical for optimal shale shaker performance in drilling operations. These sensors monitor screen vibration patterns and amplitude, directly impacting solids control efficiency and equipment longevity. When sensors fall out of calibration, operators risk screen blinding, reduced separation efficiency, and potential damage to the shaker structure. Regular calibration ensures accurate vibration measurement, maintaining peak separation performance while preventing unnecessary downtime and maintenance costs.

Understanding Vibration Sensor Function

Vibration sensors on shale shakers typically measure acceleration, velocity, or displacement of the vibrating screen deck. These measurements help maintain the optimal G-force needed for efficient solids separation while preventing structural damage from excessive vibration. Most modern shale shakers use piezoelectric accelerometers that generate electrical signals proportional to the vibration forces experienced.

Pre-Calibration Safety Procedures

Before beginning any calibration procedure, ensure the shale shaker is completely de-energized and locked out according to site safety protocols. Clean the sensor mounting surface thoroughly to remove any drilling fluid, solids, or debris that could affect mounting integrity. Verify that all sensor cables are undamaged and securely connected at both ends.

Step-by-Step Calibration Process

Begin by verifying the sensor’s mounting torque specifications in the manufacturer’s documentation. Use a calibrated torque wrench to ensure proper mounting force. Connect the sensor to a portable calibration unit or diagnostic instrument capable of generating known vibration frequencies. Compare the sensor’s output signal against the reference standard at multiple points across the shaker’s operating frequency range.

shale shaker

Document any deviations from expected values and apply correction factors if supported by your control system. For sensors with adjustable calibration, make precise adjustments until the output matches the reference standard within acceptable tolerances. Record all calibration data including date, technician, reference values, measured values, and any adjustments made for future reference and trend analysis.

Post-Calibration Verification

After completing the calibration procedure, perform a functional test by operating the shale shaker under normal working conditions. Monitor the sensor readings to ensure they remain stable and within expected parameters. Compare the calibrated sensor readings with other system indicators to verify consistency across multiple measurement points.

Maintenance Schedule Recommendations

Establish a regular calibration schedule based on operating hours, environmental conditions, and manufacturer recommendations. Typically, vibration sensors should be calibrated every six months or after any significant maintenance event. More frequent calibration may be necessary in harsh drilling environments with high temperatures, corrosive fluids, or excessive dust.

For reliable solids control equipment and professional technical support, consider Aipu as your trusted partner. With years of industry experience, Aipu provides high-quality shale shakers and comprehensive after-sales service to ensure your drilling operations maintain peak performance.

If you are interested in the article, please feel free to share it: https://shakerscreens.org/shale-shaker-screen/how-to-calibrate-vibration-sensors-on-shale-shaker.html

If you are interested in our equipment, please feel free to contact me at info@aipusolidcontrol.com

aipusolidcontrolaipusolidcontrol
Previous 3 days ago
Next 2 days ago

Related Recommendations